Tender For corrigendum : supply of auto level with all accessories, details as per annexure enclosed. [ warranty period: 30 months after the date of delivery ]
Tender For supply and fitment of industrial ro plant capacity 500 lph with 1000 l chiller tank (including water level auto cut) connected with specifications as per attached annexure a. all electrical connections and plumbing work as per site requirement. [ warranty period: 30 months after the date of delivery ]
Tender For supply of lab reagents for fully automatic biochemistry analyser machine closed system c c - sys glucose god fs 6 into32ml per pack , sys urea fs 4 into 32ml per pack , sys creatinine 4 into 32ml per pack , sys bilirubin auto total fs 4 into 32ml per pack , sys bilirubin auto direct fs 4 into 32ml per pack , sys alat gpt ifcc mod 4 into 32ml per pack , sys asat got ifcc mod 4 into 32ml per pack , sys alkaline phosphatase fs ifcc 4 into 32ml per pack , sys total protein fs 8 into 15ml per pack , sys albumin fs 4 into 32ml per pack , sys uric acid fs tbhba 4 into 32ml per pack , sys calcium as fs 8 into 15ml per pack , sys cholesterol fs 6 into 32ml per pack , sys triglyceride fs 6 into 32ml per pack , sys hdl c direct fs 4 into 32ml per pack , sys trulab one hba1c level 1 4 into 0.25ml per pack , sys trulab one hba1c level 2 4 into 0.25ml per pack , sys trucal one hba1c liquid 4 into 0.25ml per pack , sys hba1c lysing solution 1 into 500ml per pack , sys hba1c 2 into 15ml per pack , sys alkaline cleaner 1 into 2000ml per pack ) /bid number : gem/2026/b/7373341 * /dated: 06-04-2026 & & / bid document 1 / 21
Tender For supply of cuff , air duct incase bt6 876 31019 , cable between uv 343 mod , oil seal cuff 55x78x10 , packing door gasket , auto transformer , cylindrcal spring , hexagonal nt , sprint level
Tender For supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8